Industry

Water & wastewater

  • Water treatment
  • Pumping stations
  • Utility SCADA

A clean drinking water supply and effective wastewater treatment are vital. Without an OT cyber strategy, the consequences can be severe.

Organizations that miss legal and compliance requirements face financial and legal penalties.
NIS2NDAA
unattended sites operated by a single water utility
10–100

The challenge

Cybersecurity challenges

OT cyber risks in the sector are growing.

  1. Who attacks the sector

    State-backed groups, profit-driven criminals, and hacktivists.

  2. What increases exposure

    Legacy systems, growing IT/OT convergence, and staff with little OT knowledge. Network interconnection, geographic spread, and organizational complexity widen the attack surface further.

  3. Overflows and water contamination

    A manipulated OT system can cause overflows, water contamination, or in extreme cases an incident that puts lives at risk.

Solution

Industry risk management

If your OT security program is still limited, we recommend building it in two phases.

  1. Risk discovery and prioritization

    Phase 1

    Identify the critical OT functions (treatment and wastewater processing units) and estimate what it would mean if they stopped. Bring in the system operators, write realistic attack scenarios, and map the network, user permissions, supply chains, and physical security.

  2. OT cybersecurity framework (OT-CSF)

    Phase 2

    Develop formal policies and procedures based on the standards below. Typical elements: a governance model (RACI), an end-to-end operating model, regulatory compliance, an asset register, network topologies, and an incident response plan.

    Standards

    • ISA/IEC 62443
    • NIST CSF
    • NERC-CIP
    • ISO/IEC 27001/27002/27019

Related OT services

Relevant OT services

Our experts bring OT experience from the water and wastewater sector and assess the risks in your environment with a standards-based methodology. These are the services that best fit the sector's OT risks.

All OT services
  1. OT security assessment

    Shows what is on the OT network and what talks to what; at full depth it also analyzes the attack paths.

  2. Secure remote maintenance access

    Remote access for suppliers and maintenance staff through a logged access point that requires approval.

  3. OT incident response protocol

    An OT-specific procedure and playbooks, with a tabletop exercise.

Water utility specifics

What is different here

A water utility's OT environment differs from the typical single-site industrial setup in a few respects, and those differences decide where the real risk lies.

  1. Low bandwidth

    Why it matters

    GSM or radio, with limited data volume.

    What it means for the project

    Monitoring with local pre-processing.

  2. Physical access

    Why it matters

    Sites are often unguarded.

    What it means for the project

    Physical and network controls together.

  3. Central SCADA

    Why it matters

    Every site can be reached from it.

    What it means for the project

    This is where the highest Security Level belongs.

  4. Public health impact

    Why it matters

    Tampering with water quality is a direct hazard.

    What it means for the project

    Process safety systems in a separate zone.

  5. Manual operation is possible

    Why it matters

    Many processes can be run locally.

    What it means for the project

    A realistic continuity plan can be built on that.

The process

OT security in the water utility sector

Water utility OT environments are made up of many small sites on low-bandwidth links. This fragmentation is what mainly drives the risk, so the inventory and the connection map are the bulk of the work.

  1. Site inventory and connection map

    Wells, lift stations, reservoirs, the treatment plant. How each one connects to the control center: radio, GSM, leased line, or internet.

  2. Isolating the central SCADA

    The dispatch center is the most valuable target. An industrial DMZ and strict access management.

  3. Controlling access at the sites

    At unattended sites, maintenance access is logged.

  4. Continuity and manual operation

    What happens if SCADA goes down? Documenting the option of manual operation and the restore sequence.

From top to bottom: one conduit leads from the IT systems to the intermediate systems in the industrial DMZ, and another from there to the central SCADA, the dispatch center. From the center, separate conduits lead to the wells, the lift stations, the reservoirs, and the treatment plant. There is no conduit between the sites; they cannot reach each other.

Conduit
A controlled gateway between two zones. Only the defined traffic passes, in the defined direction.
No conduit
The two zones cannot reach each other.
Traffic
Allowed traffic is inspected at the gate; blocked traffic stops.
Zones and conduits at a water utility

Deliverables

What you get at the end

items handed over

  • Site and asset inventory: PLCs, RTUs, measuring instruments, firmware versions
  • Connection map between the sites and the control center
  • Zone plan that separates the control center from the sites
  • Remote access architecture for maintenance logins
  • Vulnerability report with a remediation plan optimized for low bandwidth
  • Compensating controls for site devices that cannot be updated
  • Documented playbook for switching to manual operation
  • Priorities for the next 12–18 months

Frequently asked questions

The questions we hear most

Where is the biggest risk at a water utility?

In the dispatch center. Anyone who gets in there can reach the controls of dozens of sites at once. Protecting each site matters too, but isolating the control center and tightening access to it does the most good.

How does local pre-processing work?

A device installed at the site analyzes the traffic and forwards only the deviations, not the full data. That way monitoring works even over low-bandwidth links.

What should we do about unattended sites?

At an unguarded site, opening the cabinet is equivalent to network access. Practical steps: log cabinet openings, disable or lock the physical ports, and configure the local device so that an unknown device plugged into the network triggers an alert.

Does segmentation make sense when the sites are this dispersed?

Yes, especially here. Sites should not be able to reach each other, only the control center, and the center should reach them only in the direction it needs. If one site is compromised, the rest of the network stays out of reach. It is also simpler to implement than inside a factory, because the links are point-to-point to begin with.

Contact

Ready to secure your critical systems?

Our experts will assess where your security stands and build a roadmap that fits your organization.

ARLITECH's office in Gödöllő

Visit us

You are welcome to visit our Gödöllő office in person.

Address
Centrum Office Building, 2100 Gödöllő, Dózsa György út 13, 3rd floor, office 309
Office hours
Mon–Fri, 9 a.m. to 5 p.m.
Get directions (opens in a new tab)